7 Common Wire Harness Failures and How to Prevent Them

Key Takeaways (Executive Summary)

  • The "Intermittent" Ghost: The most frustrating failure is one that comes and goes. This is usually caused by Contact Fretting (micro-motion) or a "High Resistance" crimp, not a broken wire.
  • The #1 Physical Killer: Chafing. If a harness isn't secured tightly, it vibrates against the chassis, wearing through the insulation until it shorts out.
  • Connector Back-out: If a connector isn't pushed until it "clicks" (or if the lock is defective), it will vibrate loose. This is why TPA (Terminal Position Assurance) clips are mandatory in automotive.
  • Crimp Failure: A bad crimp looks fine to the eye but fails under load. It must be prevented by Pull Force Testing during manufacturing.

When the Lights Go Out

A wire harness is the nervous system of a machine. When it fails, the machine doesn't just stop; it often behaves unpredictably. Sensors give bad data, lights flicker, and motors overheat.

Diagnosing a harness failure is difficult because the problem is often hidden inside a connector or buried deep in a cable tray.

Drawing on decades of manufacturing experience, here are the 7 most common failure modes we see and how to engineer them out of your product.

1. Insulation Chafing (The "Short Circuit")

The Symptom: Blown fuses, smoke, or dead shorts. The Cause: The harness was allowed to move. As the machine vibrates, the wire rubs against a sharp metal edge (like a chassis pass-through) or a bolt head. Eventually, the insulation wears away, and the bare copper touches the metal frame (Ground). The Prevention:

  • Grommets: Always use rubber grommets on firewall/chassis holes.
  • Fixation: Use zip ties or P-clamps every 4-6 inches to stop movement.
  • Armoring: Use braided sleeving or split loom in high-risk areas.

2. Crimp Failure (The "Pull Out")

The Symptom: The wire pulls right out of the connector housing with little force. The Cause: Under-crimping (too loose) or Over-crimping (crushed strands). The Prevention:

  • Pull Testing: Manufacturers must perform a destructive pull test (per UL 486A) at the start of every shift.
  • Crimp Height: We measure the height of the crimp to the micron to ensure the proper "gas-tight" compression ratio.

3. Contact Fretting (The "Ghost" Failure)

The Symptom: Intermittent connection. The device works fine, then fails, then works again if you wiggle the wire. The Cause: Micro-motion. Even if the connector looks plugged in, vibration causes the male pin to slide back and forth microscopically against the female socket. This rubs off the tin/gold plating, creating an oxide layer that breaks the circuit momentarily. The Prevention:

  • Gold Plating: Use Gold-on-Gold contacts for high-vibration environments (Gold doesn't oxidize).
  • High Normal Force: Choose connectors with strong spring-loaded contacts.

Comparison Table: Plating vs. Fretting Risk

Which contact plating should you choose?

Plating Material

Cost

Fretting Resistance

Best Application

Tin

Low

Low (Prone to corrosion)

Stationary appliances, standard PCs.

Gold Flash

Medium

Medium

General electronics, occasional cycle.

Gold (30 micro-inch)

High

High (Excellent)

Automotive, Aerospace, Critical Data.

Silver

High

Medium (Tarnishes)

High Power / High Current EV charging.

4. Connector Back-Out

The Symptom: The connector unplugs itself. The Cause: The operator didn't push the plug until the latch clicked, or the latch was broken. The Prevention:

  • CPA (Connector Position Assurance): A secondary red tab (common in automotive) that cannot be locked unless the connector is fully mated.
  • "Click" Auditing: During assembly, operators are trained to listen for the audible click.

5. Wicking (Solder Creep)

The Symptom: Wire breaks right behind a soldered joint. The Cause: Solder wicked up under the insulation, turning the flexible wire rigid. Vibration caused it to snap at the stress point. The Prevention:

  • Switch to Crimping: Crimping retains wire flexibility.
  • Strain Relief: If you must solder, you must add rigid heat shrink or potting to prevent the wire from bending near the solder joint.

6. Improper Strain Relief

The Symptom: Copper strands break inside the insulation near the connector (invisible failure). The Cause: The cable was bent too tightly (exceeding minimum bend radius) immediately exiting the plug. The Prevention:

  • The 10x Rule: Ensure the bend radius is >10x the cable diameter.
  • Boots: Use segmented strain relief boots to enforce a gradual arc.

7. Environmental Corrosion

The Symptom: Green crust on terminals, high resistance, overheating. The Cause: Using non-sealed connectors in a wet or humid environment. The Prevention:

  • IP Ratings: Use IP67 connectors with silicone seals.
  • Dielectric Grease: Pack connectors with grease to keep moisture out.
  • Tinned Copper: Use tinned wire instead of bare copper to resist oxidation.

Frequently Asked Questions (FAQ)

Q: How do you find a break inside a wire harness? A: We use a multimeter in "Continuity" (Beep) mode. We connect it to both ends and wiggle the harness along its length. When the beeping stops, you have found the break location.

Q: Why did my fuse blow immediately? A: This is almost always a Dead Short to ground. Check for pinched wires (caught under a bracket) or chafed insulation touching the frame. Do not just put in a bigger fuse—that leads to fire.

Q: Can I repair a damaged pin in a connector? A: Yes, if you have the right tool. You can use a Pin Extraction Toolto depress the locking barbs, pull the damaged wire out, crimp on a new terminal, and re-insert it.

Michael Wang - Senior Technical Engineer

About the Author

Michael Wang

Senior Technical Engineer

As the technical lead at TeleWire, Michael bridges the critical gap between complex engineering requirements and precision manufacturing. With deep expertise in Design for Manufacturing (DFM) and signal integrity, he oversees the technical validation of custom interconnect solutions for mission-critical automotive, industrial, and medical applications.

Powrót do blogu

Custom Cable & Wire Harness Assembly Solutions

Have a drawing or a BOM? Fill out the form. Our engineers review every submission to ensure manufacturability and provide a quick quote.

Engineering review within 24 hours
No Minimum Order Quantity (MOQ) for prototypes
ISO 9001:2015 Compliant Assembly
100% Electrically Tested
Material Certifications (RoHS/REACH) Available
Unlimited Customization Options
Cost-Efficient Scaling to Production
Premium Quality: Made in Taiwan

Request a Quote

Manufacturing Standards & Capabilities

ISO 9001 Certified Factory

TeleWire Technology operates under strict ISO 9001 Quality Management Systems. Every production run undergoes rigorous IQC (Incoming Quality Control) and IPQC (In-Process Quality Control) to ensure consistent, OEM-grade reliability for global supply chains.

IPC/WHMA-A-620 Compliance

Our assembly technicians adhere to IPC/WHMA-A-620 standards for cable and wire harness fabrication. We guarantee precision crimp height, pull-force retention, and strain relief integrity for high-vibration automotive and industrial environments.

100% Electrical Testing

Zero defect policy. 100% of finished assemblies undergo automated testing for continuity, shorts, and mis-wiring. For critical safety applications, we provide advanced VSWR testing, high-pot testing, and insertion force validation.

Custom Component Sourcing

We source genuine connectors from Amphenol, TE Connectivity, Molex, and JST, or provide cost-effective, high-quality equivalents to meet your BOM targets. Our engineering team supports rapid prototyping with low MOQs and fast turnaround times.

Have 2D or 3D drawings ready?

Talk to our engineering team for immediate design validation and DFM (Design for Manufacturing) support.

Request Technical Quote →